EN 812 covers the bump cap — a cap with a rigid insert intended to protect against striking the head on a low ceiling, a pipe, a confined space or the underside of a vehicle. The distinction from EN 397 is critical: a bump cap does not absorb the energy of a falling object and must never be substituted for a construction helmet.
Tests
- Shock absorption — a flat striker at 5 J; the transmitted force must not exceed 15 kN.
- Penetration — a striker at 2.5 J must not make contact with the headform.
Optional marking
- −20 °C / −30 °C
- Low temperature
- +50 °C
- High temperature
- F
- Molten metal splash
- 440 V a.c.
- Electrical insulation